According to GB/T759 4.9-87 standard production; that is, 85~C generally does not extend the rubber sheathing compound. It is used for general cable sheathing of conductors with long-term working temperature of 85~C. It has certain oil/heat/cold/weather resistance and high flame retardancy. It can be used directly as a marine cable sheath and can completely replace chlorine. Butadiene rubber (CR) compound.
Before aging | Tensile strength ≥ | Mpa | 11.0 | 12.7 | |
Elongation at break ≥ | % | 300 | 440 | ||
Air box aging test | Aging condition | temperature | ℃ | 75±2 | 75±2 |
time | 7×24 | 7×24 | |||
Tensile strength after aging | ≥ | Mpa | / | / | |
Rate of change ≤ | % | -30 | -3 | ||
Elongation at break after aging | ≥ | % | 200 | 402 | |
Rate of change ≤ | % | -40 | -13 | ||
Thermal extension test | Test conditions | Air temperature | ℃ | 200±3 | 200±3 |
Load time | min | 15 | 15 | ||
Mechanical stress | N/mm2 | 0.2 | 0.2 | ||
Elongation under load ≤ | % | 175 | 20 | ||
Permanent deformation after cooling ≤ | % | 15 | 4 | ||
Oil immersion test | Test conditions | Oil temperature | ℃ | 100±2 | 100±2 |
Oil immersion test | H | 24 | 24 | ||
Tensile strength change rate ≤ | % | -40 | -5 | ||
Elongation at break elongation rate ≤ | % | -40 | -3 |